KZ13 - Testing device



The KZ13 testing device is used for quick checking of basic functional parameters of RF13 transceivers (current consumption, transmitter power, receiver output voltage, receiver sensitivity), their acoustic sets (cable compactness, functionality of earphones, microphone, buttons and display), battery packs (load or no-load voltage, thermistor resistance) and for checking of RF amplifier power in the RF1325 and RF1350 sets with attenuator. The device can also be used as voltmeter (15 V and 30 V) or simple ohmmeter — short-circuit meter.

Technical parameters
Set
Documentation
Optional accessories
Nominal power supply voltage12 V
Power supply voltage range10 V to 15 V
Current consumptionmax. 60 mA
Input/output impedance at RF tests50 Ω
Test signal frequencies for receiver sensitivity testing(35, 45, 55, 65, 75, 85) MHz
Test signal output level for receiver sensitivity testing at 50 Ω load(0.7 ± 0.2) μV
Transceiver current consumption testing range3 A
RF output testing range in the 30 MHz to 88 MHz frequency range
- nominal range of use8 W
- broadening of range with UC13 attenuator80 W
AF voltage testing range3 V
Noise suppresion testing range at receiver output at the reception of RF testing signal and at the input AF noise level without this signal in (1 to 2) V range30 dB
Battery pack voltage testing range15 V
Battery pack load current4 A
Range of correct evaluation of battery pack thermistor resistance(1.3 to 91) kΩ
Measuring of external DC voltage in two ranges15 V and 30 V
Internal resistance of external voltmeter30 kΩ in 30 V range, 15 kΩ in 15 V range
Indication range at resistance measuring0 Ω to ∞
Indication of acoustic set cable compactness
- test result satisfactorygreen light
- test results not satisfactoryred light
Output level and signal frequency of acoustic set earphone excitation
- levelmin. 1 Vef at 30 Ω load
- frequency(1000 ± 200) Hz
Level of amplified microphone signal at 100 mV level and 1,000 Hz frequency(1.3 ± 0.3) V
Operating temperature range-30 °C to +60 °C
DimensionsW 200 mm x H 96 mm x D 93 mm
Weight1.5 kg