hlavička

Search by group


Search in products

Universal charger

More: 1
PN (RN): 7027.100.01
NSN: 6130160048119
Download PDF

NU1302 - Universal charger



The charger is designed to charge and discharge up to eight BP1301 or LP1302 battery packs.


Technical parameters
Battery packs
Set
Documentation
Support
Supply voltagemains 100 V to 240 V
Current consumption from mainsmax. 2.0 A
No-load current consumptionmax. 0.2 A
Protectioncut-out fuses T 3.15 A
Number of battery packs1 to 8
Standard charging BP1301
Discharging current0.28 A
Charging current0.14 A
Temperature range for standard charging initiation0 °C to +43 °C
Termination of standard chargingafter 15 hours
Quick charging BP1301
Charging current0.14 A to 1.4 A
Temperature range for quick charging initiation+10 °C to +43 °C
Termination of quick chargingafter 78 minutes, terminal voltage begins to drop
LP1302, LP20 battery pack charging
Charging currentmax. 1.6 A
Battery pack temperature range for charging initiation0 °C to +43 °C
Charging time5 hours
Termination of chargingexceeding 5 hours, current drop under 100 mA
Protection provided by enclosureIP 30
Safety of electrical appliance conforms EN 60335-1class I
Charger operating temperature range-20 °C to +50 °C
DimensionsW 330 mm x H 120 mm x D 265 mm
Weight4 kg


Switch display: Catalog | List         Select group:
Sort by:



Switch display: Catalog | List         Select group:
Sort by:



NU1302 operating instructions7027.010.02