Search by group
Search in products
Homepage » Products » Accessories » Power supplies, chargers » Power supplies, chargers • for PR20 » Chargers » Stationary charger
SC200 - Stationary chargerThe charger charges and discharges up to eight BP200 battery packs used in PR20 personal role radio. |
Technical parameters
Battery packs
Set
Documentation
Support
| Number of battery packs | 1 to 8 |
| Supply voltage mains | 100 V to 240 V ± 10 %/50 Hz to 60 Hz ± 5 % |
| Mains current consumption | max. 1.5 A |
| Current consumption no-load | max. 0.2 A |
| Charging voltage | 4.2 V to 4.4 V (in accord with programed value in battery pack) |
| Charging current | 0.2 A to 2.1 A (in accord with programed value in battery pack) |
| Discharging current | 0.4 A |
| End of charging | |
| • after 360 minutes | |
| • if the charging current drops below the limit programmed in BP200 battery pack memory | |
| Protection | cut-out fuse 2 x T 3.15 A/250 V |
| Charger operating temperatures | -20 °C to +50 °C |
| Battery pack temperatures for charging | 0 °C to maximum programmed value in battery pack |
| External dimensions [w x h x d] | 330 mm x 120 mm x 180 mm |
| Weight | max. 3 kg |
| Protection provided by enclosure | IP 30 (EN 60529) |
| High voltage test | 1500 V |
| Safety of electrical appliance conforms EN 60335-1 | class I |
| SC200 operating instructions | 7032.010.02 |

History